How to ensure the safety of oil-immersed transformer?

AddTime:2018-01-11 16:11:31   Views:     【 Big Mid Small 】   Print   Close

 How to protect the safe oil immersed transformer? The oil-immersed transformer supplier recommends that the safe fire protection measures of the oil-immersed transformer should be done to ensure the safety of the oil-immersed transformer. So what fire safety measures should be paid attention to in the daily use of baoding oil immersed transformer?

 
The oil-immersed transformer supplier summarizes the fire safety measures of baoding oil immersed transformer as follows:
 
1. The oil content of the baoding oil immersed transformer with oil content above 2500kg shall be between 600kg and 2500kg of oil filled electrical equipment, and the fire spacing shall not be less than 5m.
 
2. If the fire spacing between two adjacent oil-immersed transformers is too small to meet the fire protection requirements, fire barriers shall be set or the fire curtain shall be added at the top of the firewall.
 
3. When the oil-immersed transformer is installed outside, when the distance between the outer edge of the oil-immersed transformer and the adjacent wall is less than 0.8m, the wall shall be firewalled.
 
4, baoding oil-immersed transformer installed in the outdoor, within 5 m to the outer wall of oil-immersed transformer, the transformer under horizontal line of the total thickness with 3 m on both sides and was added to the outer 3 m range, should not be to open doors and Windows and holes; The door and fixed window on metope outside its scope, its fire resistance limit cannot be less than 0.9h.
 
5. The baoding oil-immersed transformer shall be required according to the relevant regulations, and the fixed water spraying system must be set up. If the oil-immersed transformer is set in a separate room, the door of the room shall be a class b fire door open to the outside, and the door shall be straight out of the house or corridor and shall not be opened to other rooms.
 
Baoding oil-immersed transformer is an important important power equipment in power system, so do the safety fire prevention measures of baoding oil-immersed transformer, baoding oil-immersed transformer using security is particularly important.
 
Billion in baoding electric materials co., LTD is specialized in the production of transformer baoding transformer factory manufacturers, with professional production equipment, hoisting, tooling and testing equipment, established a perfect quality management system, product performance indicators have reached the standard.
 
Company's main products: baoding dry type transformer, baoding box transformer, baoding oil immersed transformer, baoding high and low voltage complete equipment. I companies to follow "detail decides success or failure, honesty molded the future" of the enterprise purpose, adhere to "quality measuring market, seek development by innovation, to management for efficiency" business philosophy, to make my company's products are widely used in power plant, chemical, construction, mining, metallurgy, rail transportation and other industries, to meet the needs of various users, my company rely on superior product quality, thoughtful service, won the trust of our customers.